Description
Universal test Radio for the full technical maintenance and repair of FM and AM radio stations VHF
RST-430 is a multi-purpose measuring device for maintenance of communications equipment in the premises and in the field.
function
RF generator
LF generator
Frequency
Power-o-Meter
Transmitter meter load test
measurer modulation
Measuring the amount of distortion
voltmeter AC voltage
Measured parameters
The ratio of carrier / noise
the frequency of the transmitter
The ringing frequency
the frequency deviation
The sensitivity of the modulation input of the transmitter
Total harmonic distortion of the modulation characteristics of the transmitter
The sensitivity of the receiver, including the signal-to-noise method and distortion (SINAD)
Receiver output voltage
selectivity
the distortion factor
The threshold of the noise Blanker
Standard delivery
test set Radio RST-430
AC220 power adapter / 12 V
Certificate, Instrument, test lead, user manual
Cable set
Case
Specifications
1. RF generator
Baseband 90 ... 210 MHz
Permitted additional strip upon agreement with the customer (frequency step 1 kHz) 100 kHz ... 470 (527) MHz
the error of the carrier <10-6 *
Deviation in FM mode 0,1 ... 20 kHz (step 10 Hz)
setting accuracy measurement Error <10%
The output level (step 1 dBm) -60 (-80) ... -120 dBm
Level setting accuracy <3dB
Additional error of <0.1 µv
Amplitude modulation (option) 0 ... 100%
error of QAM <10%
The frequency of the modulation signal (step 1 Hz) 20 Hz ... 20 kHz
Generator 2. LF
Frequency band (step1 Hz) 20 Hz ... 20 kHz
The instability frequency <0.2 Hz
The output level (step 10 mV) 0 ... 2 V
Installation error <(0,01 + 0,03 * U) V
Total harmonic distortion <0,3%
3. Measurer modulation
Deviation FM 0,1 ... 20 kHz
Error <(0,1 + 0,1 * D) kHz
Modulation rate 0 ... 100%
Error <10%
4. Frequency meter
LF 10 Hz ... 100 kHz
RF 40 MHz To 240 MHz (... 1000 MHz)
The instability of the reference generator <10-6 *
5. Measuring distortion
Frequency band 20 Hz ... 10 kHz
The range of 1 ... 50%
Error <(5 + 5 * Kmst)%
6. DC voltmeter
The Range Is 0 ... 30 V
Error <(2 + 2 * (Uk / Umst))%
7. The AC voltmeter
The Range Of 0.02 ... 20
Frequency band 20 Hz ... 20 kHz
Error <(0,02 + 0,03 * U) V
8. Power meter
Level 0.5 to 20 watts (50 watts - W / external attenuator FAD-2, up to 100 watts - W / FAD-3, in agreement with the customer) Please note that when using difficult attenuators type of FAD or analogues for measuring parameters of a radio transmitter with an output power of 20 W, the power value is measured with the device must be multiplied by the coefficient of attenuation (fading) of an attenuator according to the formula of rett = 10 to the power of Ratt, dB / 10 )
Error <[10+ (RC / Modified Directly)]%
* If necessary, reference oscillator with a stability of 5 × 10-7 can be added.
NVRAM can be used to store test results.
The device can be supplied with a power supply that provides at least 4 hours in offline mode
Also, the battery of solar cells can be used as a power source.
Case
Dimensions: 270 × 160 × 270 mm
Characteristics
- Colour
- The black
- Operating time in automatic mode without maintenance
- 10
- Time of continuous operation without replacing the power supply unit not less than
- 240
- Number of controlled circuits
- Length
- 270
- Height
- 160
Similar products
The system for monitoring the stability of the sides of the MSR (Reutech Mining) for registration of rock displacement and mine surveying
- Vendor code
- 6418
Price Price on demand