Description
Digital combo kit.
Available in four versions.
Digital combo kit for maintenance and repair of carrier channels and data transfer equipment information structures.
Function sine wave generator broadband RMS voltmeter Narrowband (selective) RMS voltmeter frequency spectrum Analyzer monitor meter waveform
Measured parameters measure the RMS AC voltage and frequency single-ended or differential signal generating sine waves, a visual inspection of the arbitrary waveform signal spectral analysis
Standard delivery digital combo kit SVG-5 AC220 / 12V power adapter cable Set certificate, Instrument, test guide, user manual Suitcase
Specifications
Generator 1. sinusoidal
Frequency range 30 Hz ... 2,5 MHz
Step 1 Hz
the error of frequency ± 1 · 10-5% ± 1Hz
The level of the output signal when the characteristics of the termination resistance -50 dB to +14 dB
(2.5 mV ... of 3.88 In)
The output signal of the tuning step of 0.1 dB (0.01 V)
Unbalanced Output impedance 50 Ω (75 Ω)
Differential output impedance 100 Ohm (150 Ohm)
Setting the level of relative error ± 5%
2. Broadband RMS voltmeter
The range of the measured signal level -50 dB to + 40 dB
(2.5 mV ... 77.5 In)
Input frequency Range 30 Hz ... 2,5 MHz
Level measurement relative error ± 5%
A single-ended input, 50 Ω, 75 Ω, 100 Ω, 600 Ω, 1 MW
The differential input impedance of 100 Ohm, 150 Ohm, 200 Ohm, 1200 Ohm, 1 MOhm
3. Narrowband (selective) RMS voltmeter
The range of the measured signal level -50 dB to + 40 dB (2,5 mV ... 77.5 In)
Input frequency Range 30 Hz ... 2,5 MHz
Level measurement relative error ± 5%
The frequency bandwidth at -3 dB 40 Hz, 100 Hz and 1.7 kHz
A single-ended input, 50 Ω, 75 Ω, 100 Ω, 600 Ω, 1 MW
The differential input impedance of 100 Ohm, 150 Ohm, 200 Ohm, 1200 Ohm, 1 MOhm
4. Frequency meter
Measured frequency range 30 Hz ... 2,5 MHz
The level range of the measured signal 77,5 77,5 mV ... V
Level measurement relative error of ± 1 · 10-5% ± 1 Hz
5. Waveform monitor
The amplitude of the scanning range 10 mV ... 100 V
Temporary scanning range 5 NS to 5 S
Input frequency Range 30 Hz ... 2,5 MHz
Number of channels 1
Analyzer 6. Range
The maximum frequency of 4 MHz
Scale division the Interval of 5 kHz, 50 kHz, 400 kHz
Instantaneous dynamic range of 60 dB
Full 80 dB dynamic range real-time clock 10 settings in memory for each mode Retains the previous 50 measurements in voltmeter mode, continuous operation Time of 8 hours Dimensions: 360 × 380 × 140 mm